APPROVED VENT COMPONENTS
PART # DESCRIPTION
999-DV-TVK3 Archgard Flex Vent Kit with 36” (914 mm) vent length (includes 999-
DV-HTC)
999-DV-TVK5 Archgard Flex Vent Kit with 60” (1.52 M) vent length (includes 999-DV
-HTC)
999-DV-DV-HTC Archgard Horizontal termination head only
999-DV-SC Archgard Safety Cage for Horizontal termination head (999-DV-HTC)
999-DV-VSD Archgard Vinyl siding deflector
999-DV-SDA Universal Adapter, Simpson Dura-Vent / Flex
DV-GS Simpson Dura-Vent venting system
For best and safe venting performance, here are some general venting rules:
Use only Archgard or Simpson Dura-Vent direct vent systems and components.
Maintain a minimum of 1” (25mm) clearance to combustibles from the outside
surfaces of vertical vents and minimum of 1” (25mm) sides and bottom, and 2” (50mm)
from top surfaces of horizontal vents.
Observe local code restrictions, if any, regarding the installation of this type of gas appliance.
Observe the venting charts given in this manual.
Use vent spacers between the inside 4” (101mm) and outside 7” (178mm) vents at 3 ft
(915mm) intervals (Archgard Direct Vent System ONLY).
Never slope horizontal vents downwards towards the vent termination.
Maintain a minimum ¼” rise (6mm) for every linear foot (305mm) of horizontal vent.
Terminate (Horizontally) the vent only with an approved vent termination supplied by
Archgard Industries (Part # 999-DV-HTC) or Simpson Dura-Vent Termination Cap.
Terminate (Vertically) the vent only with Simpson Dura-Vent Vertical Termination Cap.
Support horizontal vents every 3 ft (915mm) to prevent sagging.
VENTING CONNECTION
The appliance will not function without being connected to a proper venting system. This
appliance may only use direct vent system supplied by Archgard Industries or Simpson Dura-
Vent direct vent systems with the appropriate adaptor dependent upon the venting guidelines
within this manual.
Please strictly follow the venting instructions for optimum performance from the
appliance and to avoid sooting and/or service calls.