OPTIMA PS1 PELLET STOVE 12
12
VENTING
Use only listed type L, PL or other suitable listed vents for pellet fuel burning
stoves. Install venting system according to the vent manufacturer’s instructions.
Strictly follow the vent manufacturer's clearances and use the proper vent
components when passing the vent through walls and ceilings. A suitable vent
termination should also be used. The performance of your pellet stove can also
be hindered by improper venting system. It is recommended that your pellet
stove be installed by a professional installer who is certified to install pellet
stoves. An improper installed and vented pellet stove can be a fire and health
hazard.
CAUTION: At no time can unlabelled parts, or substitute parts made for another venting
system be used.
Maintain the structural and vapor barrier integrity of the house when cutting holes in the walls,
ceiling and roof to suit the venting system and do any necessary framing as required by the
vent manufacturer.
NOTE: Interior vents shall be enclosed where they extend through closets, storage areas,
occupied spaces, or anyplace where the surface of the vent could be contacted by persons or
combustible materials.
The stove has a 3” diameter flue connector. Vent systems with pipes either 3” diameter or 4”
diameter (with a step up adapter) maybe used. The use of 4” diameter vent pipe system is
preferred with longer and more restrictive vent runs.
For best performance from the pellet stove, it is recommended that the total horizontal vent
runs is kept to a maximum of 10 feet. Use a maximum of two 90 elbows or equivalent and one
tee. Limit total vertical vent run to a maximum of 35 feet. This pellet stove is equipped with an
exhaust slider restrictor just upstream of the exhaust blower. The installer can use this to
balance the flow of exhaust on high draft vent configurations. This is a one time adjustment to
be done only by the installer. Loosen the 1/4” hex screw securing the slider. Push the slider in
to restrict the exhaust flow. Adjust till the stove burns properly on high and tighten the screw to
secure the slider.
The venting system of a pellet stove is pressurized. Make sure all pipe joints and connections
are air-tight to prevent the leakage of flue gas and ash. Follow the vent manufacturer’s
instructions to seal the vent system. Otherwise, apply a continuous bead of 500F (260C) high
temperature silicone sealant at the joints and securely fasten with no less than 3 sheetmetal
screws per joint or connection.
In seismically active areas, Archgard recommends that your stove be secured to the floor by
using 3” long, ¼” lag bolts in the bolt down holes on the pedestal. This is mandatory with
mobile home installations.
Do not connect this stove to a chimney serving another appliance.
Do not connect your stove to an air distribution duct.