OPTIMA PS1 PELLET STOVE 34
34
PROBLEM CAUSE CURE
Glass is Dirty
(A light white/tan accumulation is
normal)
1. Need more combustion air. Push combustion air control knob in.
2. Burn pot is clogged Clean out burn pot and poke out
clogged air holes.
3. Poor fuel Change to dry clean fuel. Use higher
quality premium pellet fuel.
4. Clogged venting system. Check for blockage in the venting
system. Check vent cap and ash
clean-out Tee.
5. Clogged combustion air inlet or
inlet pipe.
Check for blockage in the air intake
connector and duct..
6. Excessive negative pressure in
the room.
Balance pressure in the room by
opening a window.
7. Clogged exhaust blower or
exhaust passages.
Conduct ash removal maintenance.
8. Defective exhaust blower. Check for proper voltage to the stove.
If the blower runs very slow, replace
blower.
Flame Goes Out on Low or
Won't Burn Overnight On Low.
The Heat Level #3 light will flash
on the control panel to indicate
that the Proof of Fire sensor has
tripped.
1. Burn pot is clogged. Clean out burn pot and poke out
clogged air holes.
2. Not high enough pellet fuel
feed rate.
Use the LOW ADJUST button to
increase fuel feed on heat setting 1.
Select heat setting #1. Press the LOW
ADJUST button until both heat setting
1 and 4 light is lit.
3. Poor fuel Change to dry clean fuel. Use higher
quality premium pellet fuel. Increase
fuel feed rate on low by using the
LOW ADJUST button as above.
4. Combustion air set too high Gradually restrict combustion air by
pulling the control knob out.