OPTIMA PS1 PELLET STOVE 13
13
A= Clearance above grade,
veranda, porch, deck, or
balcony
12 inches (30 cm) J= Clearance to non-mechanical air
supply inlet to building or the
combustion air inlet of any other
appliance
9 inches (23 cm)
B= Clearance to window or
door that may be opened
12 inches (30 cm) K= Clearance to a mechanical
air supply inlet
3 feet (91 cm) above if
within 10 feet (3 m)
horizontally
C= Clearance to permanently
closed window
* L= Clearance above paved
sidewalk or paved driveway
located on public property
7 feet (2.13 m) +
D= Vertical clearance to
ventilated soffit located
above the terminal within a
horizontal distance of 2 feet
(61 cm) from the center line
of the terminal
* M= Clearance under veranda,
porch, deck, or balcony
12 inches (30 cm) ++
E= Clearance to unventilated soffit *
F= Clearance to outside corner *
G= Clearance to inside corner *
H= Clearance to each side of
center line extended above
meter/regulator assembly
3 feet (91 cm) within a
height 15 feet (4.5 m)
above the
meter/regulator assembly
L= Clearance to service
regulator vent outlet
3 feet (91 cm)
(+) A vent shall not terminate directly above a side walk or paved driveway that is located
between two single family dwellings and serves both dwellings
(++) Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two
sides beneath the floor.
(*) Clearances shall be in accordance with local installation codes.
TYPICAL EXHAUST TERMINATION LOCATIONS
(CHECK FOR ACCORDANCE WITH LOCAL INSTALLATION CODES)