22
THERMOSTAT / MANUAL Switch:
Selects the pellet stove operating mode. Slide the switch to MANUAL (the far right position) to
operate in user manually selectable heat level and controls. If you have a thermostat attached
and wish to have the pellet stove controlled by the device, slide the switch to HIGH/LOW (the
middle position) to operate the pellet stove in a modulating heat mode, where the thermostat
will control the heat output of the pellet stove, alternate between the lowest heat level and the
higher heat level pre-selected by the user. The ON/OFF setting (the far left position) is similar
to the previous mode, except that the stove will alternate between shutdown (stove turn
completely off) and restart to user selected heat level setting when commanded by the
thermostat. When using the thermostat, the HIGH/LOW mode is recommended. This setting
provides a more even heat output for better comfort and will extend the life of the ignition
system components. In addition, the constant visual of the flames in the stove will serve as
warning for people and pets to keep away from the stove during operations, rather then being
startled by spontaneous start-up of the stove. After switching modes, the stove should be
turned OFF and ON to reset the controls to operate in the new mode setting.
A SPST wall switch or remote control with passive on and off contact may also be used in
place of the thermostat for remote operation of the pellet stove.
ON/OFF Button:
Used to turn the stove ON and OFF.
If the stove is cold during start-up, to turn the pellet stove on, press and release the ON/OFF
button. The green light above the ON/OFF button will flash to indicate start-up cycle has
started. Fuel pellets will start to feed into the burn pot. The electric ignition system will be
automatically activated. Flames in the burn pot will appear in 3 to 7 minutes. Once the flame is
well established, the start-up cycle will end. This takes about 10 minutes. At this point, the user
will be able to make heat level adjustments in the manual mode, or the stove will carry on being
controlled by the thermostat.
If the stove is warm at restart, the ON/OFF button must be pressed down and held for two
seconds or more, until the light above the ON/OFF button is lit. The start-up cycle for the pellet
stove will be initiated. The pellet stove will be able to be adjusted in the Manual after 10
minutes or carry on being controlled by the thermostat. If you are starting a new stove or refilled
a completely empty hopper, see FUEL FEED button function below.
HEAT OUTPUT Button:
When the button is pressed, it will increase the heat output one heat level. Keep pressing the
button will cycle the heat level from 1 to 5 and back again. The convection fan speed will also
change according to the heat level. When the ON/OFF light is flashing during the start-up cycle,
the heat output button will cycle the heat level, but the stove will not respond to adjustments.
When the ON/OFF light is solid, indicating the start-up cycle has ended (about 10 minutes),
then the stove will respond, and only in manual mode. If it is a warm start-up, the ON/OFF light
will not flash indicating a start-up cycle. The stove will respond to heat adjustments only after
10 minutes from start-up.