Optima 32 - 1 14
If a wall-mounted switch or a wall-mounted thermostat is desired, Archgard recommends that
the device be wired as shown in Fig 1. This will allow the original on/off rocker switch to be
used in case the device that is mounted to the wall becomes inoperable.
Note: Archgard Industries does not manufacture or sell any wall switch or wall thermostat, and
will not extend warranty to them.
OPTIONAL WALL SWITCH OR THERMOSTAT
Thermostat / wall switch wire table
Recommended Maximum Lead Length
for two wires.
Wire Size Max. Length
14 GA. 50 Ft. (15.24 M)
16 GA. 32 Ft. (9.75 M)
18 GA. 20 Ft. (6.9 M)
20 GA. 12 Ft. (3.65 M)
22 GA. 9 Ft. (2.74 M)
Fig. 1
B
A
C
D
SUPPLY TUBE
THERMOCOUPLE LEAD
WIRE TO
PIEZO
(SPARKER)
ON/OFF SWITCH
OPTIONAL REMOTE,
WALL SWITCH, OR WALL
THERMOSTAT
A ELECTRODE
B THERMOPILE
C PILOT CAP
D THERMOCOUPLE
PILOT ASSEMBLY
VALVE CONNECTION for MILLIVOLT VALVE