Archgard Optima 32-1 Specifications Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 41
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
Optima 32 - 1 8
CLEARANCES TO COMBUSTIBLES
TOP VIEW
SIDE VIEW
Clearances to Faceplate
1” (25 mm)
1” (25 mm)
Sidewalls or Mantle Supports
CAUTION: This appliance is designed for used in any masonry or factory built wood burning
fireplace. It cannot be enclosed by combustible material and used as a built-in gas fireplace.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use
only parts specifically approved with this appliance may result in property damage or personal
injury or loss of life.
Combustible mantle allow in
shaded area. Mantle extension
maybe increased 1” (25 mm) for
each additional 1” (25 mm)
increase in clearance height.
Example: If using a 5” (127 mm)
reduce minimum height to
36” (914 mm).
If using a 4” (100 mm) reduce
minimum height to 35” (889 mm)
Note: With bay window
attached clearances
remain the same.
6” (152 mm)
Minimum Height
From Bottom of
Appliance: 37”
(940 mm) with a
6” (152 mm) mantel.
Note:
If existing wood fireplace
hearth protection is
removed it must be
replaced by a non
combustible hearth
protection extending
16” (406 mm) from the
front of the
fireplace insert.
Minimum 1” (25 mm)
clearance is required from the
faceplate (fireplace surround)
to a sidewall or mantle
support. See APPLIANCE
DIMENSIONS for surround
sizes.